5kw、7kw、10kw MMC High-Frequency Preheating Machine
Brand:
ShunhaoPayment:
LC, TTProduct Origin:
ChinaShipping Port:
XiamenSupport Service:
Life-time ServiceHigh frequency preheating machine application:
1. Electronic manufacturing, LED, LC packaging, network communication electronic components manufacturing industry, melamine tableware, bakelite powder preheating and preheating of other special materials in the early stage of molding, etc.
2. The temperature of the object can be raised to 100~150°C within a few seconds to ten seconds, so that the hardening time of the object without preheating can be reduced by two to ten.
3. It can eliminate the bubble phenomenon during molding. Even preheating can prevent bubbles, stains and marks, increase product yield, improve appearance, and reduce defective products.
The softened substances formed by high-frequency preheating can easily flow to every corner of the mold, making the mold more durable and reducing defective products!
Technical Parameters
No |
Content. |
HGY-720 |
1 |
Output |
7KW |
2 |
Power Source |
3Φ220V 380V 415V |
3 |
Power Input |
13KVA |
4 |
Oscillation Frequency |
62MHZ |
5 |
Vacuum Tube |
E3069RB |
6 |
Voltage Switching |
3-stage |
7 |
Preheating Power |
110℃ Within 60 secs |
8 |
Phenolic Resin |
1500gr |
9 |
Melamine Moulding Compound |
1200gr |
10 |
Urea Moulding Compound |
1500gr |
■ PS: Specifications are subject to change without notice.
The maintenance of HF Preheating Machine
1. Clean the dust and moisture of the upper electrode plate, lower electrode plate and roller electrode. (at any time)
2. Check whether the grounding effect of the soft copper sheets on the four sides of the upper cover is good. (once a week)
3. Clean the dust filter. (once a week)
4. Clean the dust filter at the fan port. (once a month)
5. Use dry compressed air to purge the electronic tube and its surrounding capacitors, inductance coils, and fan (once or twice a month).
6. Clean the dust and dirt on all parts (once a month).
7. Check whether the capacitors, inductors and copper sheets in the tube oscillation box are in good contact.
Whether it is fastened (3 times a year).
8. Refuel the head cover motor reducer (once every 2 years).
9. Check whether the operation of the equipment is normal (once a month).